A 1,000-watt filming light was plugged into an extension cord that ran from the server room and connected directly to the UPS. The cord was kept available for emergencies, and had also been used to power equipment when building power was unreliable. After the light was connected, the UPS began arcing and smoking, so the host shut it down and removed its power modules. One module smelled burnt, but the UPS started sparking again when restarted with that module removed, despite its display initially indicating normal operation. The host says the UPS had four power modules and roughly 12,000 volt-amps of capacity, with three modules still leaving substantial capacity. He explains that the lead-acid batteries were several years old and due for replacement, but says they were not the cause of this failure. After the unit ran for a while, it caught fire briefly; the host got a fire extinguisher but did not need to use it because the fire went out on its own. Although the UPS was out of warranty, he contacted Eaton because he felt a power-protection product should not catch fire, and an Eaton technician came to inspect it. A later update establishes that the UPS was dead and would need full replacement. A photo of its interior showed a large dark burn mark on a green circuit board, and the technician was expected to provide more information about possible service options. The technician suggested a loose connection as a possible cause, but the discussion does not establish a definitive explanation; the host also notes that the unit had been professionally installed years earlier. The segment ends with an unrelated audience question about what to do with a server, with suggestions including a Plex or file server, Minecraft, and ownCloud.
Topics · science & technology · hardware · tech · podcast · clip
Questions answered
- What triggered the smoke and arcing in the server room UPS?
- A 1,000-watt filming light was plugged into an extension cord connected to the UPS, after which the unit began arcing and smoking. The exact electrical failure was not established.
- Were old batteries identified as the cause of the UPS failure?
- No. The batteries were several years old and due for replacement, but the host said they were not the cause of this incident.
- What happened to the damaged Eaton UPS?
- It was determined to be dead and in need of full replacement. A large dark burn mark was visible on a circuit board, and the technician had not yet confirmed the cause.
- What server uses were suggested for a new server?
- Suggestions included using it as a Plex or file server, hosting Minecraft, or running ownCloud.