In deze praktijkvideo test ik de EURO-INDEX BLAUWE LIJN Eurolyzer S1 rookgasmeter tijdens de controle van een Intergas Xtreme. Ik laat zien hoe ik de gasvoordruk en rookgaswaarden meet, hoe hooglast en laaglast worden gecontroleerd en hoe de meetwaarden worden vergeleken met de officiële insteltabel. De Eurolyzer S1 meet onder andere O₂, CO₂, CO/H₂ en druk. Dit is mijn praktijkervaring als installateur; werkzaamheden aan gasverbrandingstoestellen horen bij vakbekwame professionals. Hoofdstukken: 00:00 Storing en controle Intergas Xtreme 00:42 Waarom de Eurolyzer S1? 01:19 Gasvoordruk meten 02:46 Hooglast en B-klep controleren 03:40 Meting opslaan en delen 04:59 Rookgasanalyse starten 05:23 Brandstof en rookgasprobe 06:04 O₂ meten op hooglast 07:33 Intergas-insteltabel gebruiken 08:13 Laaglast meten en afstellen 10:27 Gesloten-mantelcontrole 11:29 Meter veilig uitschakelen Meer uitleg over de EURO-INDEX Eurolyzer S1: anolso.nl Officiële productinformatie bij EURO-INDEX: euro-index.nl #EuroIndex #EurolyzerS1 #rookgasanalyse #IntergasXtreme #cvketel
AI Overview
After a flame fault was reported on an Intergas Xtreme, the installer returns to check the boiler following a recent repair to its B valve. He uses the EURO-INDEX Eurolyzer S1 to measure inlet pressure and combustion values. He describes the meter positively and demonstrates its magnetic attachment, safety lanyard, pause function, and ability to save and share measurement reports by QR code. The inlet pressure is about 28 mbar before the boiler runs at high load. At high load, the displayed pressure is 25.8 mbar, which he considers satisfactory and above his stated minimum of 20 mbar. He then moves on to the flue-gas analysis.
Topics · how-to & style · boiler maintenance · combustion analysis · heating systems · gas boiler servicing
Questions answered
- What does the EURO-INDEX Eurolyzer S1 measure during a boiler check?
- It is used for inlet pressure and flue-gas measurements. The product description lists O₂, CO₂, CO/H₂ and pressure among its measurements.
- What inlet pressure does the Intergas Xtreme show at high load?
- The meter displays 25.8 mbar at high load. The installer says this is satisfactory and above the stated 20 mbar minimum.
- How is the Intergas Xtreme's low-load oxygen value adjusted?
- After comparing the high-load O₂ reading with the natural-gas setting table, the installer runs the boiler at low load and makes small, gradual adjustments with the adjustment screw. He lets the reading settle before adjusting again.
- Why does the installer turn on the hot-water tap during the Intergas Xtreme high-load test?
- He uses the hot-water tap to cool the heat exchanger so the boiler can continue running at full load during the measurement.
- How does the closed-cover flue-gas check help assess the Intergas Xtreme?
- The installer checks whether the air supply is drawing in flue gases. With the cover closed, the O₂ reading remains stable at about 5.1, which he considers a good result.