InicioVídeos destacados y novedadesExplorarÚltimos vídeos, listas de reproducción y temasCreadoresCreadores de YouTube y sus vídeosNoticiasTitulares de los feeds de los mediosHistorialRetoma los vídeos vistos recientemente
Tema
Idioma
CuentaCuentaIniciar sesión
PrivacidadCookiesTérminosAcerca deContactoRetiradaMetodología
Cuenta
Iniciar sesión
Intergas CV-ketel storing: druk springt van 0 naar 2,4 bar?! DIT was de oorzaak
Vídeo · 0:00

Intergas CV-ketel storing: druk springt van 0 naar 2,4 bar?! DIT was de oorzaak

ANO tech world@LoodgieterDenHaagStad•28,7 mil visualizaciones•2 oct 2026•9:03

Tu valoración

Valora este vídeo de 1 a 5

Reacciones

Reacciones a este vídeo

Compartir

WhatsAppXReddit
Fuente
YT
Visualizaciones
28,7 mil
Suscriptores
141 mil
vs. media canal
1.5x
Me gusta por 100
1.2

AudioNeerlandés (original)Doblaje automático: Inglés

Descripción

Springt de waterdruk van je Intergas HR cv-ketel van 0 naar 2,4 bar of valt de druk soms terug naar nul? Dan denk je al snel aan een lekkage of een kapot expansievat. In deze praktijkvideo onderzoek ik stap voor stap wat er werkelijk gebeurt — en blijkt de oorzaak ergens anders te zitten. Wat je in deze video ziet: • de werkelijke installatiedruk vergelijken met de ketelweergave; • het expansievat meten en de werking van waterzijde, membraan en gaszijde uitleggen; • testen waarom de weergegeven druk zo snel naar 2,4 bar springt; • de vervuilde/defecte Intergas-waterdruksensor vervangen; • de installatie gecontroleerd vullen, ontluchten en opnieuw testen. De uiteindelijke diagnose: Het probleem was geen lekkage en geen defect expansievat. De waterdruksensor gaf een verkeerde waarde door. Na vervanging van de sensor en de volledige eindtest blijft de druk stabiel. HEB JE NU EEN CV-STORING? Bel ANO Loodgieter Service en Onderhoudsbedrijf: 070 888 5156. Een bestaande storing wordt eerst afzonderlijk beoordeeld. WIL JE ZEKERHEID VOOR LATER? Bekijk Basis, Plus en All-in vanaf € 8,95 per maand: anolso.nl Plus bevat naast periodiek onderhoud ook arbeid en voorrijkosten bij storingsservice. All-in bevat daarnaast onderdelen en materialen bij storingen tot maximaal € 300 inclusief btw per jaar. De eerste cv-ketelcheck bij een abonnementsaanvraag is gratis. Tijdens de aanvraag betaal je niets; het abonnement start pas na goedkeuring van de ketel en jouw akkoord. Een bestaande storing valt niet met terugwerkende kracht onder een nieuw abonnement. HOOFDSTUKKEN 00:00 Intergas CV-ketel met sterk schommelende druk 00:32 Eerst meten, dan vervangen 00:45 Expansievat testen 01:08 Expansievat is in orde 01:22 Zo werkt een expansievat 02:27 Druk springt naar 2,4 bar 02:54 De echte fout vinden 04:30 CV-ketel laten repareren 05:10 Druksensor vervangen 06:43 Installatie vullen 07:04 Vullen tot 1,8 bar 07:27 Einddruk en controle 08:13 Storing opgelost Dit is werk aan een gastoestel voor een vakprofessional. Open of repareer een cv-ketel niet zelf. Ruik je gas, is er brand of vermoed je koolmonoxide? Ga naar buiten, vermijd schakelaars en bel bij acuut gevaar 112. #Intergas #CVketel #CVstoring #Waterdruk #Expansievat #Druksensor

Start

Resumen de IA

An Intergas central heating boiler shows pressure readings that fluctuate from zero to 2.4 bar, raising concerns about a leak or a faulty expansion vessel. The technician first checks the system pressure and measures the expansion vessel, finding it at 1.5 bar and in working order. He explains that a faulty expansion vessel can cause pressure to rise as the boiler heats and fall as it cools, sometimes leading to water escaping through the pressure relief valve. When the boiler runs briefly, its displayed pressure jumps to 2.4 bar, which points instead to a faulty reading from the water pressure sensor. The technician replaces the sensor without draining the entire installation, using the shut-off valves and fitting a new retaining clip.

Temas · how-to & style · plumbing · boiler repair · heating systems

Preguntas respondidas

Why can an Intergas boiler pressure reading jump from zero to 2.4 bar?
A faulty water pressure sensor can send an incorrect pressure reading to the boiler.
What did the expansion vessel test show on the Intergas boiler?
The expansion vessel measured 1.5 bar and was found to be working properly.
Was a leak causing the boiler pressure to fluctuate?
No. The diagnosis was a faulty water pressure sensor, not a leak or a defective expansion vessel.
What pressure was the heating system filled to after the sensor replacement?
It was filled to 1.8 bar, then settled at about 1.5 bar after bleeding.
What can happen when a boiler sensor incorrectly reads zero bar?
The boiler may reduce its hot-water output, resulting in a weaker flow from the tap.

En este vídeo

ProductosIntergas HR central heating boilerIntergas water pressure sensor

Más de ANO tech world

  • Cold draughts at home? Find air leaks with a smoke test
    0:13

    Cold draughts at home? Find air leaks with a smoke test

    3,1 mil visualizaciones•hace 5 días
  • Balancing your radiators? Here’s how to check the heat distribution
    0:59

    Balancing your radiators? Here’s how to check the heat distribution

    471 visualizaciones•hace 6 días
  • Replacing and balancing ventilation unit | Itho Daalderop CVE-S ECO SP
    1:53

    Replacing and balancing ventilation unit | Itho Daalderop CVE-S ECO SP

    913 visualizaciones•hace 7 días
  • Mechanische ventilatie vervangen en inregelen | Itho Daalderop CVE-S ECO SP
    14:45

    Mechanische ventilatie vervangen en inregelen | Itho Daalderop CVE-S ECO SP

    18,7 mil visualizaciones•la semana pasada

Vídeos relacionados

  • DON'T Make THESE Mistakes Building A PC (pt. 5)
    7:07

    DON'T Make THESE Mistakes Building A PC (pt. 5)

    1,2 M visualizaciones•hace 8 años
  • This video was pain and suffering
    23:48

    This video was pain and suffering

    180,8 mil visualizaciones•el mes pasado
  • Comment avoir CarPlay dans votre Tesla... et bien plus ! Test Screenmate One
    28:44

    Comment avoir CarPlay dans votre Tesla... et bien plus ! Test Screenmate One

    33,6 mil visualizaciones•hace 2 meses
  • J’ai comparé 15 PER… voici le meilleur pour réduire ses impôts !
    28:20

    J’ai comparé 15 PER… voici le meilleur pour réduire ses impôts !

    11,5 mil visualizaciones•hace 4 días